About this calculation
Monopitch and duopitch roofs: μ from scheme 1, variants 1–3, reduction for wind drift (cl. 72), s = s0·μ and the design value.
Design basis
ShNK 2.01.07-21, Ch. 7, Annex 3 (scheme 1), Annex 5
Input data
- Snow at the site: Site; Snow zone (Annex 5 map 1); Mountain district (Table 2); Site altitude above sea level; Ground snow load s0; Mountain or poorly studied area (hatched on map 1)
- Roof: Roof profile (scheme 1); Roof pitch α; Span l (roof plan size across the ridge); A walkway or ventilation equipment runs along the ridge (variant 3)
- Load reductions (cl. 72, 73): Allow for snow drifting off by wind (cl. 72); Mean wind speed over the three coldest months v (map 2); Mean January air temperature; Building width b; Building height h; Taller buildings within 10·h1 shelter the roof from wind; Uninsulated roof of a shop with high heat release, slope > 3 %, meltwater drainage provided (cl. 73)
- Design value: Roof dead load to s0 ratio, g/s0
Output
- Coefficients μ, k, ζ, ν, c clause by clause to ShNK 2.01.07-21
- Characteristic and design loads by zone and along the height
- Diagrams and a detailed PDF, Word, Excel report
FAQ
Where do I get the ground snow load s0 and the wind pressure w0?
From maps 1 and 3 of ShNK 2.01.07-21 Annex 5 — on the Uzbekistan zone map on this site. For the settlements listed in Annex 5 Tables 1 and 3 the tabulated value applies; in the mountain districts of Table 2 the snow load depends on the site altitude.
How does ShNK 2.01.07-21 differ from SP 20.13330?
Both grew out of SNiP 2.01.07-85: the wind load is the mean component wm = w0·k·c plus the pulsating one, the snow load is s = s0·μ with the Annex 3 schemes. Zones, w0 and s0, the snow drift reduction and several tables are national.
What load safety factors apply?
Wind — γf = 1.4 (cl. 87). Snow — 1.4; 1.6 if the characteristic roof dead load is below 0.8·s0 (cl. 73). The calculators show characteristic and design values.