Lower roof or canopy next to a taller building: μ, drift length b, μ1; increased load at a parapet.
Lower roof or canopy next to a taller building: μ, drift length b, μ1; increased load at a parapet.
ShNK 2.01.07-21, Annex 3, schemes 10 and 12
From maps 1 and 3 of ShNK 2.01.07-21 Annex 5 — on the Uzbekistan zone map on this site. For the settlements listed in Annex 5 Tables 1 and 3 the tabulated value applies; in the mountain districts of Table 2 the snow load depends on the site altitude.
Both grew out of SNiP 2.01.07-85: the wind load is the mean component wm = w0·k·c plus the pulsating one, the snow load is s = s0·μ with the Annex 3 schemes. Zones, w0 and s0, the snow drift reduction and several tables are national.
Wind — γf = 1.4 (cl. 87). Snow — 1.4; 1.6 if the characteristic roof dead load is below 0.8·s0 (cl. 73). The calculators show characteristic and design values.