Kz, Kzt, Ke and the velocity pressure qz = 0.00256·KzKztKeV² against height above ground; table up to the building height.
Kz, Kzt, Ke and the velocity pressure qz = 0.00256·KzKztKeV² against height above ground; table up to the building height.
ASCE 7-22, Chapter 26 (26.10)
By site address at the official ASCE 7 Hazard Tool (asce7hazardtool.online) or from the ASCE 7-22 maps (Figure 26.5-1 for wind, Figure 7.2-1 for snow). The maps are not reproduced here — the values are entered manually.
The code equations are in US customary units (ft, mi/h, psf); input and output switch between SI and US customary, values are converted automatically and the report shows both systems.
Snow maps are given directly per Risk Category (no importance factor I_s), the winter wind parameter W2 enters the drift height equation (7.6-1), and the thermal factor C_t for heated buildings depends on the roof R-value (Table 7.3-3).