Loads to codes

Нашли неточность или ошибку в расчёте? Пожалуйста, сразу напишите на [email protected] или через форму обратной связи — буду благодарен!

ASCE/SEI 7-22 · USA

Wind pressures on a building to ASCE 7-22 (MWFRS, Directional Procedure)

Pressures p = q·Kd·G·Cp − qi·Kd·(GCpi) on windward, leeward and side walls and on roof slopes (flat, gable, hip) for wind normal and parallel to the ridge; both internal pressure signs.

Results

Detailed report

About this calculation

Pressures p = q·Kd·G·Cp − qi·Kd·(GCpi) on windward, leeward and side walls and on roof slopes (flat, gable, hip) for wind normal and parallel to the ridge; both internal pressure signs.

Design basis

ASCE 7-22, Chapters 26 and 27, Figure 27.3-1

Input data

Output

FAQ

Where do I get the basic wind speed V and the ground snow load p_g?

By site address at the official ASCE 7 Hazard Tool (asce7hazardtool.online) or from the ASCE 7-22 maps (Figure 26.5-1 for wind, Figure 7.2-1 for snow). The maps are not reproduced here — the values are entered manually.

Which units are used?

The code equations are in US customary units (ft, mi/h, psf); input and output switch between SI and US customary, values are converted automatically and the report shows both systems.

How does ASCE 7-22 differ from the previous edition?

Snow maps are given directly per Risk Category (no importance factor I_s), the winter wind parameter W2 enters the drift height equation (7.6-1), and the thermal factor C_t for heated buildings depends on the roof R-value (Table 7.3-3).

Share:VKfTgWA@Xin微博QQQzone