Wind pressures on a building to ASCE 7-22 (MWFRS, Directional Procedure)
Pressures p = q·Kd·G·Cp − qi·Kd·(GCpi) on windward, leeward and side walls and on roof slopes (flat, gable, hip) for wind normal and parallel to the ridge; both internal pressure signs.
Results
Detailed report
About this calculation
Pressures p = q·Kd·G·Cp − qi·Kd·(GCpi) on windward, leeward and side walls and on roof slopes (flat, gable, hip) for wind normal and parallel to the ridge; both internal pressure signs.
Design basis
ASCE 7-22, Chapters 26 and 27, Figure 27.3-1
Input data
Site: Input and output units; Risk category (Table 1.5-1); Jurisdiction with its own design wind speed; County; Special wind region; Basic wind speed V (3 s gust, 33 ft, Exposure C); Exposure category (26.7.3); Topographic factor Kzt (26.8); Kzt; Hill shape; H — height of hill above upwind terrain; Lh — distance upwind of crest to half-height point; x — distance from crest to building (+ downwind, − upwind); Ground elevation factor Ke (26.9); Site elevation above sea level
Building: B — plan dimension normal to wind; L — plan dimension parallel to wind; Eave height; θ — roof slope; Wind direction; Enclosure (26.12, Table 26.13-1); Gust-effect factor G (26.11); G; Kd — directionality factor (Table 26.6-1; buildings 0.85); Roof area for the Cp = −1.3 reduction (note b)
Output
Factors and pressures or loads clause by clause to ASCE 7-22
Values in SI and US customary units
Diagrams and a detailed PDF, Word, Excel report
FAQ
Where do I get the basic wind speed V and the ground snow load p_g?
By site address at the official ASCE 7 Hazard Tool (asce7hazardtool.online) or from the ASCE 7-22 maps (Figure 26.5-1 for wind, Figure 7.2-1 for snow). The maps are not reproduced here — the values are entered manually.
Which units are used?
The code equations are in US customary units (ft, mi/h, psf); input and output switch between SI and US customary, values are converted automatically and the report shows both systems.
How does ASCE 7-22 differ from the previous edition?
Snow maps are given directly per Risk Category (no importance factor I_s), the winter wind parameter W2 enters the drift height equation (7.6-1), and the thermal factor C_t for heated buildings depends on the roof R-value (Table 7.3-3).